INVT Inverter GD 10
| Features |
Svpwm control Compact design, less installation space Built-in pid with 16-step speed control Standard potentiometer and external led keypad Optional C3 filters and C2 filters Natural cooling (single-phase or three-phase 220v 0.2-0.75kw) CE requirements certified |
| Applications |
|
| Made In | China |
| Downloads | Technical Data Sheet |
| PT. Roda Rollen Indonesia Catalog |
Specifications
| FUNCTION DESCRIPTION | SPECIFICATIONS |
| RATED INPUT VOLTAGE (V) | 1PH 220V(-15%)~240V(+10%) |
| 3PH 200V(-15%)~240V(+10%) | |
| 3PH 380V(-15%)~440V(+10%) | |
| RATED INPUT FREQUENCY (HZ) | 50HZ OR 60HZ, PERMISSIBLE RANGE: 47~63HZ |
| RATED OUTPUT VOLTAGE (V) | EQUAL TO INPUT VOLTAGE WITH LESS THAN 5% ERROR |
| RATED OUTPUT FREQUENCY (HZ) | 50HZ/60HZ, FLUCTUATION RANGE: ±5% |
| CONTROL MODE | V/F CONTROL |
| MAX OUTPUT FREQUENC | 400HZ |
| SPEED RATIO | 1: 100 |
| OVERLOAD CAPACITY | 1M FOR 150% OF RATED CURRENT, 10S FOR 180% OF RATED CURRENT, 1S FOR 200% OF RATED CURRENT |
| ANALOG INPUT RESOLUTION | NO MORE THAN 20MV |
| TERMINAL DIGITAL INPUT RESOLUTION | NO MORE THAN 2MS |
| ANALOG I/O | INPUT ONE 0~10V OR 0~20MA, OUTPUT ONE 0~10V OR 0~20MA |
| DIGITAL I/O | FIVE NORMAL INPUTS, ONE Y TERMINAL OUTPUT (IN COMMON USE WITH NORMAL DIGITAL OUTPUT) AND ONE PROGRAMMABLE RELAY OUTPUT |
| COMMUNCIATION | 485 COMMUNICATION |
| INSTALLATION MODE | WALL INSTALLATION |
| AMBIENT TEMP | 10~50 celcius, DERATED IF THE AMBIENT TEMP IS ABOVE 40 celcius |
| COOLING MODE | 1PH/3PH 230V 0.2~0.75KW NATURAL COOLING |
| 1PH/3PH 220V 1.5~2.2KW, 3PH 380V 0.75~2.2KW AIR COOLING | |
| FAULT PROTECTION | PROVIDE DOZENS OF FAULT PROTECTION FUNCTIONS: OVERCURRENT, OVERVOLTAGE, UNDERVOLTAGE, OVERTEMP AND OVERLOAD |
| BRAKE UNIT | BUILT-IN BRAKE UNIT IN STANDARD CONFIGURATION |