INVT Inverter GD 20
Features |
Mini design, smaller installation space Compatible with rail and wall installation, flexible installation manner Available multi-inverter in parallel installation, more effective space-saving. |
Applications |
|
Made In | China |
Downloads | Technical Data Sheet |
PT. Roda Rollen Indonesia Catalog |
Specifications
FUNCTION DESCRIPTION | SPECIFICATIONS | |
POWER INPUT | RATED INPUT VOLTAGE (V) | 1PH 220V (-15%) -240V (+10%) |
1PH 220V (-15%) -240V (+10%) | ||
1PH 220V (-15%) -240V (+10%) | ||
RATED INPUT CURRENT(A) | REFER TO "RATED VALUE" | |
RATED FREQUENCY (HZ) | 50HZ OR 60HZ, PERMISSIBLE RANGE: 47~63HZ | |
POWER OUTPUT | RATED MOTOR CAPACITY (KW) | REFER TO "RATED VALUE" |
RATED OUTPUT (KVA) | REFER TO "RATED VALUE" | |
RATED CURRENT (A) | REFER TO "RATED VALUE" | |
RATED OUTPUT VOLTAGE (V) | EQUAL TO INPUT VOLTAGE WITH LESS THAN 5% ERROR | |
TECHNICAL CONTROL PERFORMANCE | CONTROL MODE | SVPWM, SVC |
MOTOR TYPE | ASYNCHRONOUS MOTOR | |
SPEED RANGE | 1:100 | |
SPEED CONTROL PRECISION | ± 0.2% (SVC) | |
SPEED FLUCTUATION | ± 0.3% (SVC) | |
TORQUE RESPONSE | <20MS (SVC) | |
TORQUE CONTROL PRECISION | 10% | |
STARTING TORQUE | 0.5HZ 150% (SVC) | |
OVERLOAD CAPACITY | 1M FOR 150% OF RATED CURRENT, 10S FOR 180% OF RATED CURRENT, 1S FOR 200% OF RATED CURRENT150% | |
RUNNING CONTROL CHARACTERISTICS | FREQUENCY SETUP MODE | KEYPAD DIGITS, ANALOG QUANTITY, PULSE FREQUENCY, MULTI-STEP SPEED OPERATION, SIMPLE PLC, PID, MODBUS COMMUNICATION. REALIZE SWITCHING BETWEEN THE SET COMBINATION AND THE SET CHANNEL. |
REALIZE SWITCHING BETWEEN THE SET COMBINATION AND THE SET CHANNEL. | ||
AUTO VOLTAGE ADJUSTMENT | KEEP THE OUTPUT VOLTAGE CONSTANT WHEN GRID VOLTAGE CHANGES. | |
FAULT PROTECTION | PROVIDE ALL-AROUND FAULT PROTECTION: OVERCURRENT, OVERVOLTAGE, UNDERVOLTAGE, OVERHEAT, PHASE LOSS AND OVERLOAD | |
SPEED TRACKING RESTART | REALIZE IMPACT-FREE SMOOTH STARTUP OF ROTATING MOTOR | |
AI | ONE (AI2) 0~10V/0~20MA, ONE (AI3) -10~10V | |
AO | TWO (AO1, AO2) 0~10V /0~20MA | |
DI | FOUR NORMAL INPUTS, MAX FREQUENCY: 1KHZ | |
ONE HIGH SPEED INPUT, MAX FREQUENCY 50KHZ | ||
DO | ONE Y1 TERMINAL OUTPUT, TWO PROGRAMMABLE RELAY OUTPUTS | |
RELAY OUTPUT | TWO PROGRAMMABLE RELAY OUTPUTS | |
RO1A NO, RO1B NC, RO1C COMMON PORT | ||
RO2A NO, RO2B NC, RO2C COMMON PORT | ||
CONTACT CAPACITY:3A/AC250V | ||
OTHERS | DC REACTOR | 18.5KW AND ABOVE MODELS CARRY BUILT-IN DC REACTOR IN STANDARD CONFIGURATION |
INSTALLATION MODE | 1PH 220V/3PH 380V AND BELOW AND 3PH 220V 0.75KW AND BELOW SUPPORT RAIL-TYPE AND WALL-TYPE INSTALLATION; | |
3PH 380V 4KW AND ABOVE AND 3PH 220V 1.5KW AND ABOVE SUPPORT WALL-TYPE AND FLANGE-TYPE INSTALLATION; | ||
BRAKE UNIT | BUILT-IN IN STANDARD CONFIGURATION FOR 37KW AND BELOW MODELS AND OPTIONAL FOR 45~110KW MODELS; | |
EMC FILTER | BUILT-IN C3 FILTER IS OPTIONAL FOR 3PH 380V 4KW AND ABOVE, 3PH 220V 1.5KW AND ABOVE | |
OPTIONAL FILTER: IEC61800-3 C2, IEC61800-3 C3 | ||
AMBIENT TEMP | 10~50 celcius, DERATE IF THE AMBIENT TEMP IS ABOVE 40 celcius | |
ELEVATION | BELOW 1000M, DERATE IF THE ELEVATION IS ABOVE 1000M, DERATE BY 1% PER EVERY ADDITIONAL 100M | |
PROTECTION LEVEL | IP20 | |
NOTE: THE INVERTER WITH PLASTIC SHELL SHOULD BE INSTALLED IN THE METAL DITRIBUTION BOX WHICH COMPLIES WITH IP20 AND IP3X | ||
SAFETY | MEET CE REQUIREMENT | |
COOLING MODE | AIR COOLING |